DocumentCode :
3493371
Title :
Monitoring of NMIJ standard capacitors during the last 10 years
Author :
Domae, A. ; Sakamoto, N. ; Nakamura, Y.
Author_Institution :
Nat. Metrol. Inst. of Japan (NMIJ), Nat. Inst. of Adv. Ind. Sci. & Technol. (AIST), Tsukuba, Japan
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
424
Lastpage :
425
Abstract :
Air (dry nitrogen) and fused silica standard capacitors have been monitored at NMIJ since 1999. In this paper, we describe the monitoring results of these capacitors and evaluate their behavior.
Keywords :
calibration; capacitance measurement; capacitors; measurement standards; monitoring; silicon compounds; NMIJ standard capacitor monitoring; SiO2; air standard capacitors; associated calibration system; fused silica standard capacitors; Bridge circuits; Calibration; Capacitance; Capacitors; Frequency measurement; Measurement standards; Monitoring; Nitrogen; Resistors; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5545317