Title :
Capacitive sensors for measuring the pressure between the foot and shoe
Author :
Kothari, M. ; Webster, J.G. ; Tompkins, W.J. ; Wertsch, J.J. ; Bach-y-Rita, P.
Author_Institution :
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
Abstract :
A test was conducted of a Hercules Orthoflex capacitive sensor used to measure pressure distribution under the foot for gait analysis and sensory substitution. Maximal nonlinearity for the sensor is 16%, and maximal hysteresis is 10% over the pressure range 0 to 1.3 MPa. Seven transducers in each shoe determine the distribution of pressure.<>
Keywords :
biomechanics; biomedical equipment; biomedical measurement; electric sensing devices; pressure transducers; 0 to 1.3 MPa; Hercules Orthoflex capacitive sensor; foot/shoe pressure; gait analysis; maximal hysteresis; pressure distribution; sensor nonlinearity; sensory substitution;
Conference_Titel :
Engineering in Medicine and Biology Society, 1988. Proceedings of the Annual International Conference of the IEEE
Conference_Location :
New Orleans, LA, USA
Print_ISBN :
0-7803-0785-2
DOI :
10.1109/IEMBS.1988.95056