DocumentCode :
3494836
Title :
The analysis of power loss caused by the truncation error of MPPT algorithms
Author :
Zhang, Xing ; Le Zha ; Liu, Fang ; Tao, Lei ; Chen, Wei
Author_Institution :
Sch. of Electr. Eng. & Autom., Hefei Univ. of Technol., Hefei, China
fYear :
2010
fDate :
16-18 June 2010
Firstpage :
7
Lastpage :
11
Abstract :
In order to study the power loss caused by the truncation error, a range of operating points is proposed, during which the misjudgments caused by the truncation error occur. The span of the range of operating points directly decides the amounts of tracking loss. From this point of view, the Perturbation and Observation (P&O) Method and Incremental Conductance (INC) Method are compared. Eventually, an improved algorithm which could reduce the truncation error effectively is presented. The simulation results prove the validity of the theory.
Keywords :
Arrays; Equations; Finite wordlength effects; Mathematical model; Oscillators; Photovoltaic systems; Maximum power point tracking (MPPT); incremental conductance; perturbation and observation; power loss; truncation error;
fLanguage :
English