• DocumentCode
    3494836
  • Title

    The analysis of power loss caused by the truncation error of MPPT algorithms

  • Author

    Zhang, Xing ; Le Zha ; Liu, Fang ; Tao, Lei ; Chen, Wei

  • Author_Institution
    Sch. of Electr. Eng. & Autom., Hefei Univ. of Technol., Hefei, China
  • fYear
    2010
  • fDate
    16-18 June 2010
  • Firstpage
    7
  • Lastpage
    11
  • Abstract
    In order to study the power loss caused by the truncation error, a range of operating points is proposed, during which the misjudgments caused by the truncation error occur. The span of the range of operating points directly decides the amounts of tracking loss. From this point of view, the Perturbation and Observation (P&O) Method and Incremental Conductance (INC) Method are compared. Eventually, an improved algorithm which could reduce the truncation error effectively is presented. The simulation results prove the validity of the theory.
  • Keywords
    Arrays; Equations; Finite wordlength effects; Mathematical model; Oscillators; Photovoltaic systems; Maximum power point tracking (MPPT); incremental conductance; perturbation and observation; power loss; truncation error;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics for Distributed Generation Systems (PEDG), 2010 2nd IEEE International Symposium on
  • Conference_Location
    Hefei, China
  • Print_ISBN
    978-1-4244-5669-7
  • Type

    conf

  • DOI
    10.1109/PEDG.2010.5545776
  • Filename
    5545776