DocumentCode
3495045
Title
Safe LPV controller switching
Author
Trangbaek, Klaus
Author_Institution
Dept. of Electron. Syst. Autom. & Control, Aalborg Univ., Aalborg, Denmark
fYear
2010
fDate
17-20 Nov. 2010
Abstract
Before switching to a new controller it is crucial to assure that the new closed loop will be stable. In this paper it is demonstrated how stability can be checked with limited measurement data available from the current closed loop. The paper extends an existing method to linear parameter varying plants and controllers. Rather than relying on frequency domain methods as done in the LTI case, it is shown how to use standard LPV system identification methods. By identifying a filtered closed-loop operator rather than directly identifying the plant, more reliable results are obtained.
Keywords
closed loop systems; linear systems; stability; time-varying systems; LPV controller switching; closed-loop operator; frequency domain methods; linear parameter varying controllers; linear parameter varying plants; Computational modeling; Conferences; Lyapunov method; Stability analysis; Switches; Transfer functions;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Electronics Engineers in Israel (IEEEI), 2010 IEEE 26th Convention of
Conference_Location
Eliat
Print_ISBN
978-1-4244-8681-6
Type
conf
DOI
10.1109/EEEI.2010.5662081
Filename
5662081
Link To Document