Title :
New developments in the field of PD detection and location in power cables under on-site condition
Author :
Lemke, E. ; Strehl, T. ; Russwurm, D.
Author_Institution :
LEMKE Diagnostics GmbH, Germany
Abstract :
The paper deals with new diagnostic tools for after-laying tests of power cables under on-site conditions. For diagnosis tests of medium voltage cables the CDA-procedure (complex discharge analysing procedure) has been developed, which is based on a high efficiency detection and location of PD events by application of a nonconventional transient voltage stress. For assessment of the reliability of high voltage cable and accessories a new system for sensitive PD detection under noisy condition has been developed, where directional coupler sensors are used, operating in the VHF range
Keywords :
power cable testing; CDA-procedure; PD detection; PD location; VHF range; after-laying tests; cable accessories; complex discharge analysing procedure; diagnosis tests; diagnostic tools; directional coupler sensors; high voltage cable; medium voltage cables; noisy condition; on-site condition; power cables; reliability assessment; transient voltage stress;
Conference_Titel :
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location :
London
Print_ISBN :
0-85296-719-5
DOI :
10.1049/cp:19990897