• DocumentCode
    3498083
  • Title

    Characterisation of partial discharges in oil impregnated pressboard insulation systems

  • Author

    Nerkar, Y.P. ; Narayanachar, M.N. ; Nema, R.S.

  • Author_Institution
    Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
  • Volume
    5
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    208
  • Abstract
    Partial discharge (PD) measurement and interpretation is one of the most useful diagnostic tools for quality assurance testing during the design, manufacture and life assessment of electrical equipment. Pressboard-oil insulation continues to be a major component in the insulation design of EHV transformers. As tests on practical systems are not always feasible due to cost and time factors, model systems tests are gaining importance. In the present work a model insulation system consisting of oil impregnated pressboard with uniform field electrode arrangement has been tested for its behaviour under PDs. It is shown that by defining a modified scale parameter for the Weibull distribution it is possible to take into account the effect of both smaller and larger magnitude PD pulses. The modified scale parameter serves as a good index for characterising PD behaviour in the oil impregnated pressboard insulation system studied
  • Keywords
    impregnated insulation; EHV transformers; PD pulses; Weibull distribution; diagnostic tools; electrical equipment; insulation design; life assessment; oil impregnated pressboard insulation systems; partial discharge interpretation; partial discharge measurement; partial discharges characterisation; quality assurance testing; uniform field electrode arrangement;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990922
  • Filename