Abstract :
High-voltage DC tests have traditionally been used to detect cracks and fissures, surface contamination, and moisture in rotating machine insulation systems. Not generally recognized, however, is the ability of DC testing to diagnose delaminated groundwall insulation. This impaired insulation condition is generally evaluated using AC tests, such as dissipation factor tip up and partial discharge measurements. In this paper, the ramped high voltage DC test method is described, and its ability to detect and monitor delaminated stator winding insulation is demonstrated. Supporting field data are presented and analyzed
Keywords :
machine insulation; capacitance measurement; crack detection; delaminated groundwall insulation; delaminated stator winding insulation detection; dissipation factor tip up; fissures detection; impaired insulation condition; moisture detection; partial discharge measurements; ramped high voltage DC test method; ramped high-voltage DC test method; rotating machine insulation; surface contamination detection;
fLanguage :
English
Publisher :
iet
Conference_Titel :
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-85296-719-5
Type :
conf
DOI :
10.1049/cp:19990952
Filename :
818304
Link To Document :
بازگشت