Title :
X-ray induced partial discharge phenomena in cavities and transformer oil
Author :
Lin, Guo ; Xingquan, Huang ; Li, Chengrong ; Shuchun, Liu ; Weiwei, Li ; Weidong, Zhou ; Chao, Han
Author_Institution :
Zhengzhou Electr. Power Coll., China
Abstract :
Partial discharge detection sensitivity is often limited by the availability of electrons necessary to initiate discharge. With X-ray irradiation, some interesting PD phenomena were found in cavities of solid dielectrics and in transformer oil in the authors´ laboratory tests. For small cavities, PD measuring sensitivity can be increased greatly with the use of X-ray irradiation and the effect of X-ray irradiation on PD measuring sensitivity is decreased with the size of cavities. In transformer oil, X-ray induced PD was found to be much more active compared to conventional PD under the same electric stress, which may indicate that X-ray induced PD measuring technique can be applied to oil/paper systems, such as those used in transformers
Keywords :
power transformer insulation; PD measuring sensitivity; X-ray irradiation; electric stress; oil/paper insulation systems; partial discharge phenomena; solid dielectric cavities; transformer oil;
Conference_Titel :
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location :
London
Print_ISBN :
0-85296-719-5
DOI :
10.1049/cp:19990775