DocumentCode :
3502480
Title :
Single phase inverter grid connected, controlled by fundamental harmonic calculation
Author :
Barbieri, I. ; Lambruschini, P. ; Raggio, M.
Author_Institution :
Dept. of Biophys. & Electron. Eng., Univ. of Genova, Genova, Italy
fYear :
2009
fDate :
3-5 Nov. 2009
Firstpage :
4595
Lastpage :
4599
Abstract :
In this paper a single phase inverter grid connected implementation is presented. The proposed solution is based on the calculation of the input line fundamental harmonic using a DSP processor. Our aim is to increase the inverter performance through a better synchronization with the grid and achieving a unitary power factor even in case of distorted input line, usually present in industrial environments. Typical application is, but not limited to, the exploitation of solar or wind energy. The system implementation most critical issues and results achieved with a 1.5 kW prototype are shown.
Keywords :
digital signal processing chips; harmonic analysis; invertors; DSP processor; fundamental harmonic calculation; power factor; single phase inverter grid; Digital signal processing; Frequency synchronization; Fuel processing industries; Inverters; Phase locked loops; Power harmonic filters; Prototypes; Reactive power; Voltage; Wind energy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, 2009. IECON '09. 35th Annual Conference of IEEE
Conference_Location :
Porto
ISSN :
1553-572X
Print_ISBN :
978-1-4244-4648-3
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2009.5414861
Filename :
5414861
Link To Document :
بازگشت