  • Abstract
    Characteristic impedance, compliance, and resistance of a lumped model of the systemic arterial tree are identified in the time and frequency domains during control and during aortic occlusion. There is no significant difference in the parametric values obtained using either approach. The time-domain method, however, is both simple and fast and can afford the advantage of online identification
  • Keywords
    haemodynamics; physiological models; aortic occlusion; arterial system model parameters; characteristic impedance; compliance; control; frequency domain identification; lumped model; online identification; resistance; systemic arterial tree; time-domain method; Biomedical measurements; Electrocardiography; Electromagnetic measurements; Fluid flow measurement; Frequency domain analysis; Immune system; Impedance; Power harmonic filters; Probes; Transducers;