Title :
Study of auxiliary railway power supply facing catenary transient overvoltage
Author :
Deblecker, O. ; Bertrand, P. ; Versèle, C.
Author_Institution :
Electr. Eng. Div., Fac. Polytech. de Mons, Mons, Belgium
Abstract :
In this contribution, we investigate the possibility of eliminating the crowbar circuit which is normally used to protect the auxiliary railway supply system in case of a catenary transient overvoltage. The idea is to act at the control level by suspending the operation of the auxiliary inverter when the input voltage reaches some given threshold. Experimental results are firstly presented for an inertial-type load in order to get an insight into the ensuing phenomena. Then, a theoretical analysis is carried on to explain the experimental observations, with emphasis on the freewheeling sequence of the inverter output currents. The subsequent voltage oscillations across the inverter switches are also justified. Considering a numerical example with realistic parameters values, it is shown that the freewheeling stage is not dangerous for the power devices of the auxiliary inverter. The switch voltages oscillations could however be destructive, depending on the value of the inverter dc input voltage at the time these oscillations start (rather than their peak value itself).
Keywords :
invertors; overvoltage protection; power supplies to apparatus; railways; auxiliary inverter; auxiliary railway power supply; catenary transient overvoltage; crowbar circuit; freewheeling sequence; freewheeling stage; inverter switches; power devices; Cables; Circuits; Inverters; Leg; Power supplies; Power system protection; Rail transportation; Surges; Switches; Voltage control;
Conference_Titel :
Industrial Electronics, 2009. IECON '09. 35th Annual Conference of IEEE
Conference_Location :
Porto
Print_ISBN :
978-1-4244-4648-3
Electronic_ISBN :
1553-572X
DOI :
10.1109/IECON.2009.5415038