• DocumentCode
    3506818
  • Title

    Control method for a combined active filter system employing a current source converter and a high pass filter

  • Author

    Fukuda, Shoji ; Endoh, Takayoshi

  • Author_Institution
    Hokkaido Univ., Sapporo, Japan
  • fYear
    1993
  • fDate
    19-21 April 1993
  • Firstpage
    621
  • Lastpage
    628
  • Abstract
    This paper describes a control method with a combined filter system which senses load current, source current and line voltage to create reference signals for an active filter. The transfer function of the active filter is identified and is used for the control system design. It is shown that the source current feedback is most effective to suppress the harmonic-enlarging effects due to parallel resonance and the harmonic current generated by source harmonic voltages. A small setup controlled by a DSP was built, and the validity of the proposed method was demonstrated by experimental results.<>
  • Keywords
    active filters; control system synthesis; digital control; digital signal processing chips; feedback; harmonics; high-pass filters; power convertors; transfer functions; voltage control; DSP; active filter; control system design; current source power convertors; digital control; feedback; harmonic current; harmonic voltages; high pass filter; parallel resonance; reference signals; transfer function; voltage control; Active filters; Control systems; Digital signal processing; Feedback; Power harmonic filters; Power system harmonics; Reactive power; Resonance; Transfer functions; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Conversion Conference, 1993. Yokohama 1993., Conference Record of the
  • Conference_Location
    Yokohama, Japan
  • Print_ISBN
    0-7803-0471-3
  • Type

    conf

  • DOI
    10.1109/PCCON.1993.264184
  • Filename
    264184