    The Electronic Armament Centre (CELAR: Centre d´Electronique de l´Armement) has evaluated the use of a relatively low frequency ultra-wide band short pulse measurement facility to characterize target electromagnetic signatures. Specific measurement instrumentation has been developed and implemented. The initial measurement trial began at the beginning of 1998 and led to the establishment of a database on various targets. These measurements made it possible to interpret, in the time domain, the signatures and to work out holograms. Images were calculated either in the time or the frequency domain
  • Keywords
    backscatter; military radar; pulse measurement; radar cross-sections; UWB short pulse sensor; electromagnetic backscattering; holographic imaging; measurement instrumentation; military target; radar cross section; Antenna measurements; Backscatter; EMP radiation effects; Electromagnetic measurements; Frequency; Pulse measurements; Radar cross section; Radar measurements; Sensor phenomena and characterization; Time measurement;