DocumentCode
3509612
Title
Development of a noninvasive continuous blood pressure measurement and monitoring system
Author
Islam, Md Minarul ; Rafi, Fida Hasan Md ; Mitul, Abu Farzan ; Ahmad, Mohiuddin ; Rashid, M.A. ; Malek, Mohd Fareq bin Abd
Author_Institution
Dept. of Electr. & Electron. Eng., Khulna Univ. of Eng. & Technol., Khulna, Bangladesh
fYear
2012
fDate
18-19 May 2012
Firstpage
1085
Lastpage
1090
Abstract
Non invasive continuous blood pressure measurement system is more useful than conventional blood pressure measurement systems. The arterial system is extraordinarily well regulated blood delivery network in human body. It responds very quickly according to the body movements like altered body position, or in sudden excitation. So now a day´s continuous blood pressure monitoring devices are becoming more essential. Many types of blood pressure measurement devices are available. Those devices allow only few blood pressure readings in every 10 minutes. In contrast to them, we develop a very low cost noninvasive continuous blood pressure measurement and monitoring system. It measures blood pressure using volume oscillometric method and photoplethysmography technique during a long time period continuously. The rate of change of blood volume in an organ such as finger has a linear relationship with blood pressure. This rate of change of blood volume in finger is measured by an optical sensor network which estimates blood pressure. It displays the numerical value of systolic and diastolic blood pressure in a mini LCD. Our developed system is reliable, accurate and less expensive.
Keywords
biological organs; biomedical equipment; blood; blood pressure measurement; optical sensors; patient monitoring; photoplethysmography; blood delivery network; blood pressure measurement devices; blood pressure monitoring devices; body movements; diastolic blood pressure; finger; human body; miniLCD; noninvasive continuous blood pressure measurement system; noninvasive continuous blood pressure monitoring system; optical sensor network; organ; photoplethysmography; systolic blood pressure; volume oscillometric method; Biomedical monitoring; Fingers; Monitoring; Position measurement; Reliability; Standards; Volume measurement; Noninvassive measurement; continuous blood pressure; monitoring system; oscillometric method;
fLanguage
English
Publisher
ieee
Conference_Titel
Informatics, Electronics & Vision (ICIEV), 2012 International Conference on
Conference_Location
Dhaka
Print_ISBN
978-1-4673-1153-3
Type
conf
DOI
10.1109/ICIEV.2012.6317436
Filename
6317436
Link To Document