Two unusual forms of ESD, internal chair discharges and multiple small metal-to-metal discharges from "jingling change", have caused severe field problems in electronic equipment. These forms of ESD are not covered by any current standard. A review of previous work, new measured data, and examples of problems that have occurred are presented.
Keywords
electric fields; electrostatic discharge; reliability; static electrification; ESD; ESD standards; electronic equipment; field problems; internal chair discharges; jingling change-induced discharges; measured data; multiple small metal-to-metal discharges; Electromagnetic interference; Electronic equipment; Electronic equipment testing; Electrostatic discharge; Electrostatic interference; Equipment failure; Fault location; IEC standards; Immunity testing; System testing;