DocumentCode :
3509976
Title :
Unusual forms of ESD and their effects
Author :
Smith, Douglas C.
Author_Institution :
Auspex Syst. Ltd., Santa Clara, CA, USA
fYear :
1999
fDate :
28-30 Sept. 1999
Firstpage :
329
Lastpage :
333
Abstract :
Two unusual forms of ESD, internal chair discharges and multiple small metal-to-metal discharges from "jingling change", have caused severe field problems in electronic equipment. These forms of ESD are not covered by any current standard. A review of previous work, new measured data, and examples of problems that have occurred are presented.
Keywords :
electric fields; electrostatic discharge; reliability; static electrification; ESD; ESD standards; electronic equipment; field problems; internal chair discharges; jingling change-induced discharges; measured data; multiple small metal-to-metal discharges; Electromagnetic interference; Electronic equipment; Electronic equipment testing; Electrostatic discharge; Electrostatic interference; Equipment failure; Fault location; IEC standards; Immunity testing; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Overstress/Electrostatic Discharge Symposium Proceedings, 1999
Conference_Location :
Orlando, FL, USA
Print_ISBN :
1-58637-007-X
Type :
conf
DOI :
10.1109/EOSESD.1999.819080
Filename :
819080
Link To Document :
بازگشت