• DocumentCode
    351088
  • Title

    Analysis of errors in the measurement of chopped impulses

  • Author

    Gobbo, R. ; Pesavento, G.

  • Author_Institution
    Dept. of Electr. Eng., Padova Univ., Italy
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    17
  • Abstract
    IEC 60-2 with its new approach to the qualification of industrial measuring systems covers also the case of chopped LI (lightning impulses), with time to chopping down to 500 ns. The paper discusses the procedure for the possible qualification of a reference measuring system in terms of the parameters of the USR, the sources of error and their dependence on the actual waveform: the influence of the shape of the voltage collapse depending upon the way in which the chopping action is obtained is also discussed
  • Keywords
    lightning; 500 ns; HV measurement; IEC 60-2; LV measurement; USR parameters; chopped lightning impulses; chopping action; industrial measuring systems qualification; measurement errors analysis; reference measuring system; voltage collapse shape;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990497
  • Filename
    820149