DocumentCode
3511348
Title
Adaptive control for ZVS three phase full active bridge converter with ARCN
Author
Molina, J.M. ; García, O. ; Asensi, R. ; Alou, P. ; Oliver, J.A. ; Cobos, J.A.
Author_Institution
Centro de Electron. Ind., Univ. Politec. de Madrid, Madrid, Spain
fYear
2012
fDate
5-9 Feb. 2012
Firstpage
1324
Lastpage
1330
Abstract
This paper presents an adaptive control for the auxiliary circuit, called ARCN (Auxiliary Resonant Commutating Network), used to achieve ZVS in full active bridge converters under a wide load range. Depending on the load conditions, the proposed control adapts the timing of the ARCN to minimize the losses. The principle of operation and implementation considerations are presented for a three phase full active bridge converter, proposing different methods to implement the control according to the specifications. The experimental results shown verify the proposed methodology.
Keywords
adaptive control; power convertors; zero voltage switching; ZVS three phase full active bridge converter; adaptive control; auxiliary resonant commutating network; load conditions; zero voltage switching; Adaptive control; Bridge circuits; Inductance; Inductors; MOSFETs; Parasitic capacitance; Zero voltage switching;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition (APEC), 2012 Twenty-Seventh Annual IEEE
Conference_Location
Orlando, FL
Print_ISBN
978-1-4577-1215-9
Electronic_ISBN
978-1-4577-1214-2
Type
conf
DOI
10.1109/APEC.2012.6165991
Filename
6165991
Link To Document