• DocumentCode
    351207
  • Title

    Lightning current induced magnetic field distribution measurement technique on a mock airplane fuselage test setup

  • Author

    Li, George Shiao-Yi Tsai ; Sebo, Stephen A. ; Schweickart, Daniel L. ; Walko, Lawrence C. ; Horwath, John C. ; Spyker, Russell L. ; Webb, Gary L.

  • Author_Institution
    Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    254
  • Abstract
    A new technique is suggested far the measurement of the magnetic field distribution outside and inside along a 10 m long by 1 m diameter aluminum test cylinder during simulated lightning surges. An example is given: the measured ratio of the voltage outputs of two magnetic flux density probes at two test points, one outside and one inside a closed aluminum test cylinder, was about 4700
  • Keywords
    aircraft testing; 1 m; 10 m; closed aluminum test cylinder; lightning currents; magnetic field distribution measurement; magnetic flux density probes; mock airplane fuselage test setup; simulated lightning surges; test points;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990555
  • Filename
    820635