DocumentCode :
3513836
Title :
Analysis and implementation of voltage stress in performance degradation test
Author :
Zhang, Fang ; Cai, Jinyan ; Zhu, Yanhui
Author_Institution :
Opt. & Electron. Dept., Ordnance Eng. Coll., Shijiazhuang, China
fYear :
2009
fDate :
20-24 July 2009
Firstpage :
433
Lastpage :
436
Abstract :
PARD (Periodic and Random Deviation) of controllable power is important to the study on performance degradation of electronic equipment under voltage stress with different PARD. Taking switching power as an example in this paper the PARD signal is analyzed in time domain and frequency domain. We find that it is closer to real situation when peak-peak value (Vp-p) and characteristic frequency are selected as the main characteristic parameters of DC power PARD. At the same time the hardware of voltage with different PARD is implemented using the method of AC superposed DC.
Keywords :
differentiating circuits; frequency-domain analysis; network topology; pulse circuits; time-domain analysis; AC superposed DC circuit; characteristic frequency; circuit topology; differential circuit; electronic equipment; frequency domain analysis; peak wave producing circuit; performance degradation; power PARD; power periodic and random deviation; pulse circuit; switching power; time domain analysis; voltage stress; Degradation; Electronic equipment; Frequency domain analysis; Hardware; Performance analysis; Signal analysis; Stress control; Testing; Time domain analysis; Voltage control; AC superposed DC; performance degradation; power PARD;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Reliability, Maintainability and Safety, 2009. ICRMS 2009. 8th International Conference on
Conference_Location :
Chengdu
Print_ISBN :
978-1-4244-4903-3
Electronic_ISBN :
978-1-4244-4905-7
Type :
conf
DOI :
10.1109/ICRMS.2009.5270154
Filename :
5270154
Link To Document :
بازگشت