• DocumentCode
    3513836
  • Title

    Analysis and implementation of voltage stress in performance degradation test

  • Author

    Zhang, Fang ; Cai, Jinyan ; Zhu, Yanhui

  • Author_Institution
    Opt. & Electron. Dept., Ordnance Eng. Coll., Shijiazhuang, China
  • fYear
    2009
  • fDate
    20-24 July 2009
  • Firstpage
    433
  • Lastpage
    436
  • Abstract
    PARD (Periodic and Random Deviation) of controllable power is important to the study on performance degradation of electronic equipment under voltage stress with different PARD. Taking switching power as an example in this paper the PARD signal is analyzed in time domain and frequency domain. We find that it is closer to real situation when peak-peak value (Vp-p) and characteristic frequency are selected as the main characteristic parameters of DC power PARD. At the same time the hardware of voltage with different PARD is implemented using the method of AC superposed DC.
  • Keywords
    differentiating circuits; frequency-domain analysis; network topology; pulse circuits; time-domain analysis; AC superposed DC circuit; characteristic frequency; circuit topology; differential circuit; electronic equipment; frequency domain analysis; peak wave producing circuit; performance degradation; power PARD; power periodic and random deviation; pulse circuit; switching power; time domain analysis; voltage stress; Degradation; Electronic equipment; Frequency domain analysis; Hardware; Performance analysis; Signal analysis; Stress control; Testing; Time domain analysis; Voltage control; AC superposed DC; performance degradation; power PARD;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability, Maintainability and Safety, 2009. ICRMS 2009. 8th International Conference on
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4244-4903-3
  • Electronic_ISBN
    978-1-4244-4905-7
  • Type

    conf

  • DOI
    10.1109/ICRMS.2009.5270154
  • Filename
    5270154