Title :
Fabrication of calibration standards for the millimeter- and sub-millimeter wavelength ring-centered waveguide flange
Author :
Yu, Qiang ; Hesler, Jeffrey L. ; Kerr, Anthony R. ; Li, Huilin ; Weikle, Robert M., II ; Barker, N. Scott
Author_Institution :
Charles L. Brown Dept. of Electr. & Comput. Eng., Univ. of Virginia, Charlottesville, VA, USA
Abstract :
This paper introduces a new fabrication approach for calibration shims with ring-centered waveguide flanges using KMPR based microfabrication. The high precision of the ring-centered flange imposes more strict restrictions on the dimensions of corresponding waveguide shims, making conventional machining techniques less competitive. Taking advantage of the KMPR microfabrication process, a set of accurate calibration standards (λ/4, 5λ/8 and 7λ/8) for the WR-2.2 band (330 GHz-500 GHz) ring-centered waveguide flange are fabricated and characterized. As a reference, a set of calibration standards for regular UG-387 flanges is prepared using the same approach. Measurement results and the comparison between the two sets of λ/4 waveguides are presented in the paper.
Keywords :
calibration; flanges; measurement standards; micromachining; millimetre wave measurement; submillimetre wave measurement; KMPR; KMPR microfabrication process; UG-387 flange; WR-2.2 band ring-centered waveguide flange; calibration shims; calibration standard fabrication; frequency 330 GHz to 500 GHz; machining technique; millimeter wavelength ring-centered waveguide flange; submillimeter wavelength ring-centered waveguide flange; Calibration; Flanges; Optical device fabrication; Radio astronomy; Resists; Standards; Standards; micro-fabrication technique; millimeter wave; photolithography; ring-centered waveguide flanges; sub-millimeter wave; waveguides;
Conference_Titel :
Microwave Measurement Conference (ARFTG), 2011 77th ARFTG
Conference_Location :
Baltimore, MD
Print_ISBN :
978-1-61284-959-1
Electronic_ISBN :
978-1-61284-960-7
DOI :
10.1109/ARFTG77.2011.6034571