DocumentCode
3517584
Title
Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli
Author
Lee, H.K. ; Suehiro, J. ; So, M.H. ; Hara, M. ; Lee, D.C.
Author_Institution
Bucheon Tech. Coll., South Korea
Volume
2
fYear
1997
fDate
25 -30 May 1997
Firstpage
1136
Abstract
We measured the survivability ratio of Escherichia coli suspensions in an impulse generator. The experiment are performed by using fixed R and C values and variable L values in an RLC discharging network and comparing the survivability in each case. The results show that the pulse waveform parameters in the discharging circuit are the critical factor in the sterilization
Keywords
bioelectric phenomena; biological effects of fields; biological techniques; biotechnology; cellular effects of radiation; network parameters; pulse generators; Escherichia coli suspensions; RLC discharging network parameters; electrical sterilization; impulse generator; pulse waveform parameters; survivability ratio; Chromium; Educational institutions; Electric variables measurement; Electrodes; Power supplies; Pulse circuits; Pulse measurements; RLC circuits; Switches; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
Conference_Location
Seoul
Print_ISBN
0-7803-2651-2
Type
conf
DOI
10.1109/ICPADM.1997.616649
Filename
616649