Title :
Packaging for radiation resistant X-ray detectors
Author :
Lohse, Thomas ; Oppermann, Martin ; Metasch, Reneé ; Zerna, Thomas ; Seilmayer, Martin ; Wolter, Klaus-Jürgen
Author_Institution :
Electron. Packaging Lab. (IAVT), Dresden Univ. of Technol., Dresden, Germany
Abstract :
Today non-destructive evaluation techniques become more and more important. Consequently, X-ray detectors are suitable tools to get information about specimens. In comparison to the already established scintillation principle, the direct converting method on the basis of semiconductor materials delivers several advantages. Hence, it is necessary to speed this measurement method and develop appropriate packages for these assemblies. In this paper the method of direct converting X-ray line detectors as well as their packaging and relevant aspects are introduced.
Keywords :
X-ray detection; electronics packaging; silicon radiation detectors; measurement method; nondestructive evaluation techniques; radiation resistant X-ray detectors; scintillation principle; semiconductor materials; Absorption; Anodes; Detectors; Integrated circuits; Materials; Packaging; X-ray detectors;
Conference_Titel :
Electronics Technology (ISSE), 2010 33rd International Spring Seminar on
Conference_Location :
Warsaw
Print_ISBN :
978-1-4244-7849-1
Electronic_ISBN :
978-1-4244-7850-7
DOI :
10.1109/ISSE.2010.5547276