Abstract :
In this research work, the behavior of medium voltage stator bar groundwall insulation that is subjected to steep-front voltage pulses, at various repetition rates and temperatures, is studied. The test conditions include; pulse voltage amplitudes up to 3.5 kVp, pulse switching frequencies up to 3 kHz, and in ambient temperatures of 23 and 155 degC. During the aging process, the surface temperature is monitored with an infrared camera as a means for determining the locations of the highest temperature and therefore the highest regions of PD activity. Visual observations confirm degradation of the groundwall insulation in the regions of highest temperature and PD measurements show increased activity and reduced PD inception with aging.
Keywords :
insulation testing; invertors; machine insulation; partial discharge measurement; stators; 155 C; 23 C; 3 kHz; 3.5 kV; aging process; ambient temperatures; infrared camera; inverter-fed pulses; medium voltage stator bar groundwall insulation; pulse switching frequencies; pulse voltage amplitudes; steep-front voltage pulses; surface temperature; Aging; Infrared surveillance; Insulation; Medium voltage; Pulse inverters; Stators; Switching frequency; Temperature measurement; Temperature sensors; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2006 IEEE Conference on
Conference_Location :
Kansas City, MO
Print_ISBN :
1-4244-0547-5
Electronic_ISBN :
1-4244-0547-5
Type :
conf
DOI :
10.1109/CEIDP.2006.311970
Filename :
4105471
Link To Document :
بازگشت