Title :
A method to detect the deterioration of HTV silicone rubber under corona discharge
Author :
Liang, Ying ; Ding, Lijian ; Li, C.R. ; Yang, Kun ; Tu, Youping
Author_Institution :
Beijing Key Lab. of High Voltage & EMC, North China Electr. Power Univ., Beijing
Abstract :
This paper has investigated the thermally stimulated current (TSC) characteristics of the deteriorated HTV silicone rubber under varied corona discharge duration, the hydrophobicity, scanning electron microscopy (SEM), and Fourier transform infrared (FTIR) of the corresponding test samples have also been measured. The experimental results show that the TSC characteristics of HTV silicone rubber gradually varied with the corona deterioration process, and it has relationship with the change of its hydrophobicity, SEM, and also FTIR. As a result, it could be suggested that the TSC characteristics might be used as an effective index for assessing the corona deterioration of HTV silicone rubber.
Keywords :
Fourier transform spectra; corona; infrared spectra; scanning electron microscopy; silicone rubber insulators; thermally stimulated currents; FTIR spectra; Fourier transform infrared spectra; HTV silicone rubber; SEM; corona deterioration process; corona discharge; hydrophobicity; scanning electron microscopy; thermally stimulated current characteristics; Corona; Electrodes; Insulation; Microstructure; Performance evaluation; Pollution measurement; Rubber; Scanning electron microscopy; Testing; Voltage;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2006 IEEE Conference on
Conference_Location :
Kansas City, MO
Print_ISBN :
1-4244-0547-5
Electronic_ISBN :
1-4244-0547-5
DOI :
10.1109/CEIDP.2006.311981