DocumentCode
3526105
Title
Wide energy range gamma-ray calibration facility
Author
Kroupa, M. ; Janout, Z. ; Kralik, M. ; Krejci, F. ; Owens, A. ; Pospisil, S. ; Quarati, F. ; Solc, J.
Author_Institution
Inst. of Exp. & Appl. Phys., Czech Tech. Univ. in Prague, Prague, Czech Republic
fYear
2010
fDate
Oct. 30 2010-Nov. 6 2010
Firstpage
352
Lastpage
356
Abstract
A number of radiation-related applications in space such as γ-ray detection demands a flexible and wide-range γ-ray source which can serve as calibrating and testing facility for γ-ray detectors and γ-ray sensitive devices. A dedicated wide energy range γ-ray facility with adjustable and modular segments designed for γ-ray detector calibration and testing was built. Gamma rays are obtained from thermal neutron capture, which is the most suitable and cost efficient way how to provide discrete γ rays with energy above 3 MeV and of reasonable intensity. With appropriate and interchangeable targets the facility can generate γ rays with energy up to 10 MeV. Target materials of elements with high thermal neutron capture cross-section such as chrome, iron, chlorine, nickel and titanium provide suitable spectra. As neutron source 252Cf or 241Am-Be radionuclide sources with emission rate around 106 neutrons/s are used. The emitted fast neutrons are moderated by a modular interchangeable system of elements containing light materials such as graphite, water, heavy water or paraffin. Different geometries and moderator-target combinations have been tested and optimized; the best of them are presented. The facility is optimized with respect to space applications and needs by the European Space Agency (ESA). Performance of the facility is demonstrated by calibration spectra measured by HPGe and scintillator detectors (LaBr3, NaI(Tl)).
Keywords
calibration; gamma-ray detection; gamma-ray production; germanium radiation detectors; neutron sources; radioactive sources; solid scintillation detectors; 241Am-Be radionuclide source; 252Cf neutron source; European Space Agency; HPGe detector; LaBr3 detector; NaI(TI) detector; calibration spectra measurement; gamma-ray calibration facility; gamma-ray detection; gamma-ray detector calibration; gamma-ray generation; gamma-ray sensitive device; modular interchangeable system; neutron emission rate; scintillator detector; thermal neutron capture cross-section; wide-range gamma-ray source; Calibration; Detectors; Gamma rays; Materials; Neutrons; Physics; Sensitivity; detector calibration; gamma spectroscopy; prompt gamma-rays; thermal neutron capture;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location
Knoxville, TN
ISSN
1095-7863
Print_ISBN
978-1-4244-9106-3
Type
conf
DOI
10.1109/NSSMIC.2010.5873779
Filename
5873779
Link To Document