DocumentCode :
3526359
Title :
Evaluation of a standardization method for 22Na sealed point sources for various measurement conditions
Author :
Sato, Yasushi ; Murayama, Hideo ; Oda, Keiichi ; Nishikido, Fumihiko ; Yoshida, Eiji ; Sato, Tomohiko ; Hasegawa, Tomoyuki ; Inadama, Naoko ; Yamaya, Taiga ; Yamada, Takahiro ; Unno, Yasuhiro ; Yunoki, Akira
Author_Institution :
Nat. Inst. of Adv. Ind. Sci. & Technol., Nat. Metrol. Inst. of Japan, Tsukuba, Japan
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
427
Lastpage :
430
Abstract :
We have devised a standardization method for a sealed point source that can be applied to nuclides such as 22Na that emit a positron and at least one gamma ray. This method is based on coincidence counting of annihilation radiation and gamma rays using a scintillation detector array. In the present study, we performed Monte Carlo simulations to examine this method for various measurement conditions. EGS5 Monte Carlo simulation results confirm that this method is effective for measurements of a 22Na sealed point source using BGO scintillation detector arrays.
Keywords :
Monte Carlo methods; gamma-ray detection; solid scintillation detectors; standardisation; 22Na sealed point source; BGO scintillation detector arrays; EGS5 Monte Carlo simulation; annihilation radiation; scintillation detector array; standardization method; Arrays; Detectors; Materials; Monte Carlo methods; Photonics; Robustness; Standardization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5873794
Filename :
5873794
Link To Document :
بازگشت