Title :
Detectors for intense, pulsed active detection
Author :
Jackson, S.L. ; Allen, R.J. ; Apruzese, J.P. ; Commisso, R.J. ; Hinshelwood, D.D. ; Mosher, D. ; Murphy, D.P. ; Ottinger, P.F. ; Schumer, J.W. ; Swanekamp, S.B. ; Young, F.C. ; Cooperstein, G. ; Hunt, A.W. ; Seipel, H.A. ; Gagliardi, M.A.
Author_Institution :
Plasma Phys. Div., Naval Res. Lab., Washington, DC, USA
fDate :
Oct. 30 2010-Nov. 6 2010
Abstract :
In intense, pulsed active detection, a single, intense pulse of radiation is used to induce photofission in fissionable material, increasing its detectability. The Mercury pulsed-power generator was converted to positive polarity (+3.7 MV, 325 kA, 50-ns FWHM) to drive an intense, pulsed radiation source based on the FIGARO active detection concept. The probing radiation source consisted of an ion-beam diode and a thick PTFE (Teflon) converter where 6-7 MeV γ-rays were produced via the 19F(p,αγ)16O reaction. A suite of radiation detectors was used both to detect the presence of irradiated fissionable material and to characterize the probing radiation source. Four types of detectors were used for the source characterization. Thermoluminescent dosimeters were used to measure the angular distribution of the dose associated with x-rays and γ-rays from the ion-beam diode. Plastic scintillator-photodiode detectors were used to characterize the time dependence of this dose. A plastic scintillator-photomultiplier detector was used to monitor the γ-ray intensity of the probing radiation source and to monitor changes in the production of background neutrons by the diode and PTFE converter. A set of rhodium foil activation counters was used to measure the absolute yield of these background neutrons. Two types of detectors with comparable sensitivities were used to measure delayed neutrons resulting from photofission: 3He proportional counters and a 6Li-loaded-glass-scintillator detector. The neutron detection rate from each detector following the probing radiation pulse was over 100 times higher with depleted uranium present than with lead.
Keywords :
gamma-ray detection; gamma-ray production; helium-3 counters; neutron detection; nuclear electronics; photofission; photomultipliers; solid scintillation detectors; thermoluminescent dosimeters; 19F(p,alha+gamma)16O; 3He proportional counter; 6Li-loaded-glass-scintillator detector; FIGARO active detection; X-ray dose rate; angular distribution measurement; background neutron measurement; background neutron production; fissionable material; gamma-ray dose rate; gamma-ray intensity monitoring; gamma-ray production; ion-beam diode; mercury pulsed-power generator; neutron detection rate; photofission material; plastic scintillator-photodiode detector; pulsed active detection; pulsed radiation source; radiation detector; radiation source; rhodium foil activation counter; thermoluminescent dosimeter; Anodes; Detectors; Electron tubes; Inspection; Lead; Neutrons; X-rays;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
Print_ISBN :
978-1-4244-9106-3
DOI :
10.1109/NSSMIC.2010.5873815