• DocumentCode
    3528021
  • Title

    The CDF Run II Silicon Detector: Performance and aging studies

  • Author

    Corbo, Matteo

  • Author_Institution
    LPNHE, Univ. Paris VI, Paris, France
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    927
  • Lastpage
    930
  • Abstract
    The Silicon Detector at the CDF Experiment in Run II has been collecting data steadily in a hard radiation environment for the last 9 years. This has led to the presence of some aging effects, such as type-inversion of the substrate and increase of the intrinsic noise, that are carefully monitored in order to maintain the detector performance at the highest level and to predict the useful lifetime of the different sensors. In this presentation, a summary of the studies is given as well as the current conclusions and expectations for the future of the detector.
  • Keywords
    ageing; radiation monitoring; silicon radiation detectors; CDF Run II silicon detector; CDF experiment; aging effect; hard radiation environment; radiation monitoring; Aging; Detectors; Monitoring; Noise; Silicon; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5873897
  • Filename
    5873897