DocumentCode
3529195
Title
Advances in on-line monitoring of polymer injection molding process
Author
Franca, D. Ramos ; Wen, S.-S.L. ; Jen, C.K. ; Nguyen, K.T. ; Hebert, H.
Author_Institution
IMI, Nat. Res. Council of Canada, Boucherville, Que., Canada
Volume
1
fYear
1997
fDate
5-8 Oct 1997
Firstpage
807
Abstract
On-line ultrasonic monitoring of the polymer injection molding process is carried out. The completion of the filling is monitored by two ultrasonic transducers (UTs) and the flow front speed is evaluated by one UT. The variation of elastic properties, shrinkage and solid-liquid interface development of the injected part during the solidification stage are observed. The flow speed is also measured using two clad buffer rods with two UTs. All measurements are performed using 5 MHz UTs
Keywords
casting; monitoring; polymers; shrinkage; solidification; ultrasonic materials testing; ultrasonic transducers; 5 MHz; clad buffer rods; elastic properties; filling; flow front speed; flow speed; on-line monitoring; on-line ultrasonic monitoring; polymer injection molding process; shrinkage; solid-liquid interface development; solidification stage; ultrasonic transducers; Councils; Filling; Fluid flow measurement; Injection molding; Monitoring; Performance evaluation; Polymers; Ultrasonic transducers; Ultrasonic variables measurement; Velocity measurement;