• DocumentCode
    3529630
  • Title

    An efficient implementation on a low cost FPGA for photon detection in nuclear imaging

  • Author

    Fysikopoulos, Eleftherios ; Georgiou, Maria ; Efthimiou, Nikolaos ; David, Stratos ; Loudos, George ; Matsopoulos, George

  • Author_Institution
    Sch. of Electr. & Comput. Eng., Nat. Tech. Univ. of Athens, Athens, Greece
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    1408
  • Lastpage
    1412
  • Abstract
    The aim of this study is to propose and evaluate a simple, open source, data acquisition (DAQ) tool, which provides accurate results for nuclear imaging applications. For this purpose a Xilinx Spartan3E Starter Kit, which is one of the simplest Field Programmable Gate Arrays (FPGA) evaluation boards, was used. The system has been evaluated using a positionsensitive photo-multiplier (PSPMT) at the energy produced by 99mTc sources. Two dual channel, external, 12-bit analog to digital converters (ADC) with a sampling rate of 1Msps per channel were used. The tool was designed using Xilinx´s Embedded Development Kit (EDK) and was based in Xilinx´s Microblaze soft-core processor. A reference multiparameter based data acquisition system using nuclear instrumentation modules (NIM) was used for the evaluation of the proposed system. Two different algorithms for pulse height estimation were applied; the maximum height approximation method and the Gaussian approximation. A second PSPMT and a Silicon Photomultiplier (SiPM) were used for further evaluation of image quality and energy spectrum respectively. Results have shown that the FPGA based data acquisition system i) provides accurate digitization of the PSPMTs anode signals in various conditions and ii) gives similar energy spectra when SiPMs are used.
  • Keywords
    analogue-digital conversion; computerised instrumentation; data acquisition; field programmable gate arrays; microprocessor chips; nuclear instrumentation; photomultipliers; photons; DAQ tool; FPGA evaluation board; Gaussian approximation; NIM; PSPMT; Si; SiPM; Xilinx Embedded Development Kit; Xilinx Microblaze soft-core processor; Xilinx Spartan3E starter kit; analog to digital converter; data acquisition tool; energy spectrum; field programmable gate array evaluation board; image quality; maximum height approximation method; nuclear imaging application; nuclear instrumentation module; photon detection; position-sensitive photomultiplier; pulse height estimation; silicon photomultiplier; word length 12 bit; Biomedical imaging; Data acquisition; Detectors; Energy resolution; Estimation; Field programmable gate arrays; Instruments; Data acquisition (DAQ); Embedded Development Kit (EDK); Field Programmable Gate Arrays (FPGA); Position Sensitive Photo-multipliers (PSPMT); Silicon Photo-multiplier (SiPM);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874004
  • Filename
    5874004