DocumentCode
3529738
Title
Development of a CF4 recuperation plant for the Cathode Strip Chambers detector at the CERN Compact Muon Solenoid experiment
Author
Capeans, M. ; Guida, R. ; Haider, S. ; Hahn, F. ; Rouwette, S.
fYear
2010
fDate
Oct. 30 2010-Nov. 6 2010
Firstpage
1433
Lastpage
1438
Abstract
Cathode Strip Chambers (CSC) are used in the end-cap region of the Muon spectrometer for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). The nominal gas mixture contains 40% Ar, 50% CO2 and 10% CF4. The main function of CF4 is to prevent polymerisation processes that would result on deposits on the wires as proved by long-term ageing tests performed during the past few years. CF4 is an expensive gas; the current gas operational cost in the CMS CSC is about 100 kCHF/year, in a closed-loop gas system that is operated with a 90% re-circulation rate. Unfortunately, it is not possible to increase the re-circulation fraction because N2 from air constantly diffuses into the detector. However, the possibility of recuperating the CF4 would offer several advantages, both in terms of cost and flexibility of operation. A CF4 recuperation plant has been proposed. The present layout is based on four stages: (1) CO2 bulk separation in a polymeric membrane, (2) residual CO2 removal in a 4 Å molecular sieve, followed by (3) CF4 adsorption a in 13X molecular sieve and (4) CF4 compression and storage. A prototype with all the functionalities (automatic actions, on-site regeneration, and gas analysis with an infrared device) has been built and it is currently being tested. Preliminary results are presented in this paper. During the tests, several candidate membranes have been characterized and the optimizations of both CO2 and CF4 adsorption stages have been carried out. The overall CF4 recuperation efficiency is about 65%. N2 contamination in the recuperated gas is substantially reduced.
Keywords
multiwire proportional chambers; particle spectrometers; CERN CMS experiment; CF4 compression; CF4 recuperation plant; CF4 storage; Large Hadron Collider; candidate membranes; cathode strip chambers detector; closed-loop gas system; compact muon solenoid; end-cap region; long-term ageing tests; molecular sieve; muon spectrometer; nominal gas mixture; polymeric membrane; polymerisation processes; Argon; Detectors; Molecular sieves; Prototypes; Strips; Wires;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location
Knoxville, TN
ISSN
1095-7863
Print_ISBN
978-1-4244-9106-3
Type
conf
DOI
10.1109/NSSMIC.2010.5874009
Filename
5874009