• DocumentCode
    3532454
  • Title

    Image registration and perfusion imaging: Application to dynamic circular cardiac CT

  • Author

    Isola, Alfonso A. ; Schmitt, Holger ; Van Stevendaal, Udo ; Begemann, Philipp G. ; Grass, Michael

  • Author_Institution
    Philips Res. Eur. - Hamburg, Hamburg, Germany
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    2362
  • Lastpage
    2365
  • Abstract
    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce X-ray dose and limit motion artifacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the data set with maximum contrast enhancement is selected as reference data set. The complete series is aligned with respect to this reference volume. The results are evaluated on pig data comparing perfusion measures using the non-registered versus the registered data set. The reduced spatial misalignment leads to an improved characterization of myocardial perfusion confirming the potential of this method.
  • Keywords
    biological tissues; cardiovascular system; computerised tomography; electrocardiography; haemorheology; image enhancement; image motion analysis; image reconstruction; image registration; image sequences; medical image processing; ECG-triggered acquisitions; X-ray dose; cardiac volumes; contrast enhancement; dynamic circular cardiac CT; dynamic volume sequences; elastic 3D image registration; fast rotating gantries; image reconstruction; large area detector computed tomography systems; motion artifacts; myocardial perfusion parameters; perfusion imaging; small motion pattern variations; spatial misalignment; stable heart rate; Computed tomography; Image reconstruction; Image registration; Myocardium; Optimization; Spline; Myocardial perfusion; computed tomography; image registration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874208
  • Filename
    5874208