• DocumentCode
    3532653
  • Title

    Failure Analysis on the BGA Solder Joint

  • Author

    Mo Yunqi ; He Wei ; Wang Shou-Xu ; Wang Yang ; Wu Xiang-Hao ; He Bo ; Zhang Xuan-Dong

  • Author_Institution
    Dept. of Appl. Chem., Univ. of Electron. Sci. Technol. of China, Chengdu
  • fYear
    2009
  • fDate
    28-29 April 2009
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The analysis process and methods of a failure BGA solder joint have been studied by a failure analysis case for an actual BGA package sample with XRD, cross section analysis and SEM&EDS analysis. The analysis results show that the cracks are the main failure causes of the BGA solder joints. The position of cracks appeard between the IMC and PCB pad and the interface of solder and IMC. The main reason of cracks is that excessively thick and irregular Sn-Ag and Sn-Cu IMC reduced the mechanical robustness of the solder joints and when the solder joints were subject to external stress, cracking occurred. The contribution of failure analysis to quality control of BGA mounting was also displayed.
  • Keywords
    X-ray diffraction; ball grid arrays; failure analysis; mountings; scanning electron microscopy; solders; BGA; EDS; SEM; XRD; cross section analysis; failure analysis; mountings; solder joint; Chemical technology; Electronics packaging; Failure analysis; Helium; Intermetallic; Scanning electron microscopy; Soldering; Tensile stress; X-ray detection; X-ray scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Testing and Diagnosis, 2009. ICTD 2009. IEEE Circuits and Systems International Conference on
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4244-2587-7
  • Type

    conf

  • DOI
    10.1109/CAS-ICTD.2009.4960817
  • Filename