DocumentCode :
3534946
Title :
Experimental feasibility of multi-material decomposition imaging in small animal SPECT/CT system
Author :
Cho, Hyo-Min ; Kim, Hee-Joung ; Lee, Chang-Lae ; Pivovaroff, Michael ; Seo, Youngho
Author_Institution :
Dept. of Radiol. & Biomed. Imaging, Univ. of California, San Francisco, CA, USA
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
3187
Lastpage :
3189
Abstract :
The photon counting detectors such as cadmium zinc telluride (CZT) and cadmium telluride (CdTe) have powerful advantages compared to energy integrating detectors. CZT or CdTe can detect individual gamma-ray or x-ray photon with energy discrimination. In recent years, energy-resolving and material decomposition x-ray imaging based on photon counting detectors has attracted attention from biomedical imaging researchers. We evaluated a large-area (20 cm × 20 cm) CZT detector originally built as a radionuclide detector for a small animal SPECT/CT system in combination of a microfocus x-ray source with a general goal of developing a material-decomposition imaging method. In this paper, we present experimental results from a feasibility study of multi-material decomposition imaging using the developed small animal SPECT/CT system. Our small animal SPECT/CT system has the unique capability to arrange detectors and sources flexibly. For the multi-material decomposition scan, the CZT detector and the x-ray tube were re-arranged in line. List-mode data of a phantom containing 7 different materials, with a range of densities and atomic numbers, illuminated by x-ray were acquired. The x-ray exposure conditions were: 50 kVp and 0.5 mA with 1.5-mm Al filtration. The acquired image was corrected for bad and hot pixels, gain, and offset. The attenuation profiles of each material were calculated against the x-ray energy. Measured attenuation profiles of each material were in a good agreement with the reference data of the NIST physics laboratory. In this study, we demonstrated that multi-material decomposition imaging is experimentally feasible using the photon-counting CZT detector and polychromatic x-ray. Since our system allows rotation and a large active area of CZT, we will acquire material-decomposition data tomographically in the near future.
Keywords :
X-ray detection; cadmium compounds; gamma-ray detection; phantoms; photon counting; semiconductor counters; single photon emission computed tomography; solid scintillation detectors; CZT detector; CdTe; CdZn; X-ray photon; biomedical imaging; cadmium telluride; cadmium zinc telluride; gamma-ray; multimaterial decomposition imaging; phantom; photon counting detectors; radionuclide detector; small animal SPECT/CT system; Attenuation; Computed tomography; Detectors; Materials; Photonics; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5874392
Filename :
5874392
Link To Document :
بازگشت