Title :
Validation of CT-based attenuation correction for multi-pinhole PSF reconstruction for small-animal SPECT
Author :
Austin, Derek W. ; Feng, Bing ; Mintzer, Robert A. ; Chen, Mu ; Gregor, Jens ; Stuckey, Alan C. ; Wall, Jonathan S.
Author_Institution :
Preclinical Solutions, Siemens Med. Solutions, USA, Inc., Knoxville, TN, USA
fDate :
Oct. 30 2010-Nov. 6 2010
Abstract :
We recently reported a numerical ray-tracing algorithm for calculating the point-spread function (PSF) used in 3-D ordered subsets expectation maximization (OSEM) reconstruction of single and multi-pinhole collimated single photon emission computed tomography (SPECT) images. In this work, we evaluated the performance of our PSF reconstruction method with and without X-ray CT-based attenuation correction (AC) and dual energy window scatter correction (SC). X-ray CT data was acquired to create the attenuation maps. SPECT data was acquired using 99mTc phantoms and 5-pinhole tungsten collimators with 1.0 mm diameter pinholes. With no corrections applied, an axial image slice of a 3 cm diameter cylinder uniformly filled with mTc showed a 13% dip near the center of the phantom. When AC and SC were applied, the cross-section through an axial slice showed a desirable flattened profile that dipped only 3%. We also scanned a mouse with 99mTc implantable sources that had negligible self-attenuation. The sources were first scanned in air for calibration. Our results show that the reconstructed SPECT images with no corrections underestimated the activity for each mTc implanted source by 12% on average, while the image with AC and SC underestimated the activity by only 3.3% on average. We repeated all of the experiments with 125I phantoms but did not apply SC to the 125I data. With no correction applied, an axial slice of a 3 cm diameter cylinder uniformly filled with 125I dipped 25 % near the center of the phantom. After applying AC, the 125I image profile no longer dipped but rather was overcorrected by 4.5%. Similarly, the reconstructed image of the 125I implants with no correction underestimated the activity of each source by 23% on average, while the 125I image with AC overestimated the activity in the sources by 4.6% on average. These results have shown that our PSF- - reconstruction method with CT-based attenuation correction improved the quantitative accuracy of SPECT images for representative 99mTc and 125I studies.
Keywords :
calibration; collimators; computerised tomography; data acquisition; image reconstruction; medical image processing; phantoms; physiological models; radioactive tracers; single photon emission computed tomography; technetium; tungsten; 5-pinhole tungsten collimators; 99mTc implantable sources; 99mTc phantoms; Tc; W; X-ray CT-based attenuation correction; axial image slice; calibration; data acquisition; dual energy window scatter correction; image reconstruction; multipinhole PSF reconstruction; point-spread function; size 1 mm; size 3 cm; small-animal SPECT; Attenuation; Computed tomography; Image reconstruction; Mice; Phantoms; Reconstruction algorithms; X-ray imaging;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
Print_ISBN :
978-1-4244-9106-3
DOI :
10.1109/NSSMIC.2010.5874423