Abstract :
This paper describes the results of the residual AC breakdown voltage investigated using different initial voltage steps for dry-cured power XLPE cables. Also we investigated the cause of the breakdown and the starting points of the electrical-trees which occurred. Based on the relationship between the residual AC breakdown voltages and the starting points of electrical-trees, we will discuss the influence of the initial voltage step on the residual AC breakdown voltage
Keywords :
XLPE insulation; ageing; electric breakdown; insulation testing; life testing; power cable insulation; power cable testing; trees (electrical); accelerated water immersion aging test; dry-cured XLPE power cables; electrical trees; initial voltage step; lifetime; residual AC breakdown voltage; starting points; Accelerated aging; Breakdown voltage; Electric breakdown; Life estimation; Partial discharges; Power cables; Semiconductivity; Testing; Underground power cables; Wire;