Abstract :
Many hundreds of partial discharge test results on about 100 operating motors and generators have been reviewed. In the majority of results, the position of the partial discharges with respect to the 600 Hz phase angle was as expected from conventional partial discharge theory, as well as laboratory experiments. However, perhaps 25490 of the PPA plots were “abnormal” in some way. Yet these patterns are real, and are not due to noise, nor are they artifacts of the measurement system. Researchers developing pattern recognition techniques for PD pulses should be aware that patterns from operating high voltage equipment may be much more complex than the patterns obtained in laboratory apparatus
Keywords :
electric generators; electric motors; insulation testing; machine insulation; machine testing; partial discharges; pattern recognition; 600 Hz; PPA plots; generators; high voltage equipment; insulation tests; motors; partial discharge test; pattern recognition techniques; pulse phase patterns; Dielectrics and electrical insulation; Hydraulic turbines; Instruments; Partial discharge measurement; Partial discharges; Phase measurement; Pulse generation; Pulse measurements; Stator windings; Working environment noise;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulating Materials, 1995. International Symposium on
Conference_Location :
Tokyo
Print_ISBN :
4-88686-047-8
Type :
conf
DOI :
10.1109/ISEIM.1995.496546
Filename :
496546
Link To Document :
بازگشت