DocumentCode
3538819
Title
Evaluation of mechanical characteristics for a new vacuum pressure impregnation insulation system
Author
Nakayama, Akinobu
Author_Institution
Rotating Machinery Technol. Dev. Lab., Fuji Electr. Corp. Res. & Dev. Ltd., Kanagawa, Japan
fYear
1995
fDate
17-20 Sep 1995
Firstpage
503
Lastpage
506
Abstract
Fuji Electric has recently introduced a vacuum pressure impregnation (VPI) system for air-cooled turbine generator stator windings in the 30~260MVA class. To accompany this, we have also developed a new insulation system for this VPI system, called the F-resin/GII insulation system. This insulation system is equipped with characteristics for operation over a long period of time and excellent heat cycle resistance. In this article, an evaluation of the mechanical characteristics of the main insulation for the new VPI insulation system is described
Keywords
bending; composite insulating materials; machine insulation; stators; turbogenerators; 30 to 260 MVA; F-resin/GII; Fuji Electric; VPI insulation system; air-cooled turbine generator stator windings; bending; mechanical characteristics; vacuum pressure impregnation; Capacitive sensors; Dielectrics and electrical insulation; Electric resistance; Machine windings; Performance evaluation; Thermal resistance; Thermal stresses; Vacuum systems; Vacuum technology; Voltage;