• DocumentCode
    3540458
  • Title

    A DFT technique to increase the resolution of AC RMS power supply current monitoring of complex analogue circuits

  • Author

    Chalk, C.D. ; Zwolinski, M. ; Wilkins, B.R.

  • Author_Institution
    Dept. of Electron. & Comput. Sci., Southampton Univ., UK
  • fYear
    1997
  • fDate
    35726
  • Firstpage
    42614
  • Lastpage
    42618
  • Abstract
    RMS AC supply current monitoring with the addition of the novel DFT technique presented in this paper shows an increase in fault coverage for an embedded opamp from only 2.5% to over 70%. During a test, the effective width-length ratio of the transistors that draw the most AC current is reduced, causing the supply current drawn by other parts of the circuit that might be faulty to contribute relatively more to the overall supply current, allowing detection of faults. The results of Monte Carlo fault simulations demonstrate the principle. The most significant advantages of this DFT technique are increased fault coverage; small (1%) area overhead; and low impact on the performance of the circuit
  • Keywords
    analogue integrated circuits; AC RMS power supply current monitoring; DFT technique; Monte Carlo fault simulations; complex analogue circuits; embedded opamp; fault coverage; fault detection;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Testing Mixed Signal Circuits and Systems (Ref. No: 1997/361), IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19971200
  • Filename
    663244