DocumentCode :
3540729
Title :
Investigation of leakage in broadband RF and microwave attenuation measurement systems
Author :
Widarta, Anton
Author_Institution :
Nat. Metrol. Inst. of Japan, AIST, Tsukuba, Japan
fYear :
2013
fDate :
9-13 Sept. 2013
Firstpage :
1365
Lastpage :
1367
Abstract :
A simple technique to estimate the attenuation uncertainty due to the leakage in RF and microwave high attenuation is presented. The principle applied in this technique is to execute high attenuation measurements of the device under test (DUT) in networks having phase differences of 0, 90, 180, 270 degrees, created using particular length of addition lines. Investigation on the measurement of 100 dB step attenuator showed the limit of attenuation uncertainty due to leakage is 0.01 dB.
Keywords :
attenuation measurement; electromagnetic wave scattering; magnetic leakage; microwave measurement; DUT; RF high attenuation measurements; attenuation uncertainty estimation; broadband RF attenuation measurement systems; device under test; leakage; microwave high attenuation measurement system; phase differences; step attenuator; Attenuation; Attenuation measurement; Frequency measurement; Phase measurement; Radio frequency; Receivers; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetics in Advanced Applications (ICEAA), 2013 International Conference on
Conference_Location :
Torino
Print_ISBN :
978-1-4673-5705-0
Type :
conf
DOI :
10.1109/ICEAA.2013.6632473
Filename :
6632473
Link To Document :
بازگشت