DocumentCode :
3540802
Title :
The influence of the conducting inductance in the auxiliary resonant commutated pole inverter
Author :
Iida, Katsuji ; Sakuma, Takeshi ; Mechi, Abdallah ; Matsuo, Hirofumi ; Kurokawa, Fujio
Author_Institution :
Tech. Res. Lab., Toyo Electr. Manuf. Co. Ltd., Kanagawa, Japan
Volume :
2
fYear :
1997
fDate :
22-27 Jun 1997
Firstpage :
1238
Abstract :
The auxiliary resonant commutated pole (ARCP) inverter is well-known by its small EMI and switching loss. However, in the high voltage-high power application, there exist some problems such as the difficulty of the complete ZVS realization, influence of the conducting inductance and so forth. In this paper, the characteristics of the ARCP inverter are analysed, with consideration of the conducting inductance influence. The useful analytical results are obtained and confirmed by the experiment
Keywords :
commutation; inductance; invertors; switching circuits; ZVS realization; auxiliary resonant commutated pole inverter; conducting inductance; high voltage-high power application; low EMI; switching loss; zero voltage switching; Diodes; Inductance; Inductors; Inverters; Rail transportation; Resonance; Switches; Switching circuits; Thyristors; Zero voltage switching;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1997. PESC '97 Record., 28th Annual IEEE
Conference_Location :
St. Louis, MO
ISSN :
0275-9306
Print_ISBN :
0-7803-3840-5
Type :
conf
DOI :
10.1109/PESC.1997.616922
Filename :
616922
Link To Document :
بازگشت