DocumentCode :
3543537
Title :
A 128×128 ultrasonic transducer hybrid array
Author :
Erikson, K. ; Hairston, Allen ; Nicoli, Anthony ; Stockwell, Jason ; White, Tim
Author_Institution :
Lockheed Martin IR Imaging Syst., Lexington, MA, USA
Volume :
2
fYear :
1997
fDate :
5-8 Oct 1997
Firstpage :
1625
Abstract :
Ultrasonic imaging in the low MHz frequency range with large, dense arrays presents many design and fabrication challenges. Conventional ultrasound systems use micro-coaxial cable to connect the array to the front end electronics. While coax technology has improved dramatically in the past decade, interconnecting 16384 array elements with separate wires remains a formidable challenge. In addition to this practical issue, the capacitance of a long coaxial cable (~40 pF/m) is much larger than that of a typical 2D array element (<1 pF), creating a voltage divider that severely reduces the signal-to-noise ratio of the channel. A 2D composite piezoelectric receiver array bonded directly to four large custom integrated circuits is described. This 128×128 (16384 total) element Transducer Hybrid Array (THA) of 200 μm unit cell spacing is intended for a 3D real-time imaging system for medical and underwater applications. By reducing the interconnect length to less than 20 μm, cable capacitance is no longer a problem. Massively parallel, on-chip signal processing enables true real-time three-dimensional imaging. Favorable tradeoffs using composite piezoelectric materials, enabled by this high-density flip-chip interconnection technology are discussed
Keywords :
application specific integrated circuits; biomedical electronics; biomedical transducers; biomedical ultrasonics; flip-chip devices; piezoelectric transducers; real-time systems; ultrasonic imaging; ultrasonic transducer arrays; underwater sound; 128 by 128 array; 128×128 ultrasonic transducer hybrid array; 16384 total; 20 mum; 200 mum; 2D composite piezoelectric receiver array; 3D real-time imaging system; THA; cable capacitance; composite piezoelectric materials; design; fabrication; four large custom integrated circuits; high-density flip-chip interconnection technology; interconnect length; large dense arrays; low MHz frequency range; massively parallel on-chip signal processing; medical applications; ultrasonic imaging; underwater applications; Capacitance; Coaxial cables; Coaxial components; Fabrication; Frequency; Integrated circuit interconnections; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers; Underwater cables;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1997. Proceedings., 1997 IEEE
Conference_Location :
Toronto, Ont.
ISSN :
1051-0117
Print_ISBN :
0-7803-4153-8
Type :
conf
DOI :
10.1109/ULTSYM.1997.663306
Filename :
663306
Link To Document :
بازگشت