Title :
100 kV high frequency transformer/rectifier package with bipolar voltage output
Author :
Giesselmann, Michael ; Vollmer, Travis ; Carey, William
Author_Institution :
ECE-Dept., Texas Tech Univ., Lubbock, TX, USA
Abstract :
A 100kV high frequency transformer / rectifier package was designed and tested which is capable of dual polarity operation. The primary of the transformer is driven by an H-Bridge at a frequency of 20 kHz. The transformer has two HV-coax output cables with a grounded shield on each cable. One of the HV output cables is designated as the positive output terminal whereas the other output cable is designated as the negative output terminal. The shields of both output cables are always grounded. In addition, the core of the transformer is grounded. To obtain either positive or negative output voltage, either of the HV center conductors of the output coax cables is grounded. If the center conductor of the coax cable designated as negative output is grounded, positive voltage is obtained from the coax cable designated as positive output is obtained and vice versa.
Keywords :
bridge circuits; coaxial cables; conductors (electric); earthing; high-frequency transformers; power transformers; rectifiers; H-bridge; HV center conductors; HV-coax output cables; bipolar voltage output; dual polarity operation; frequency 20 kHz; grounded shield; high frequency transformer-rectifier package; voltage 100 kV; Cable shielding; Conductors; Educational institutions; Oil filled cables; Rectifiers; Voltage measurement;
Conference_Titel :
Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
Conference_Location :
San Francisco, CA
DOI :
10.1109/PLASMA.2013.6633266