DocumentCode :
3546482
Title :
Transfer and test of a 1 MV LTD generator at CEA
Author :
Toury, Martial ; Cartier, Frederic ; Caron, Michel ; Etchessahar, Bertrand
Author_Institution :
DAM, CEA, Gramat, France
fYear :
2013
fDate :
16-21 June 2013
Firstpage :
1
Lastpage :
1
Abstract :
Summary form only given. The 1 MV Linear Transformer Driver (LTD) generator has been transferred from the site Polygône d´Expérimentation de Moronvilliers to the site of Gramat by the CEA. In order to mitigate both the volume and the duration of the moving operation, only the inner stalk and the ancillary equipment (high voltage dump tanks, trigger generator, vacuum system, command bay, etc.) were disconnected. The 10 cavities remained compressed together in their own support stand. The generator was reassembled in less than two months. All cavities were opened to check visually that the inner components did not move inside and to carry out some preventive maintenance operations (rebuilding liquid resistors, inspecting insulators, etc.). The generator is now being operated with the same performance as before the transfer. Also, for the first time on this generator, several radiographic shots have been fired with a conical Self Magnetic Pinch (SMP) diode.
Keywords :
pinch effect; pulse generators; CEA; LTD generator; SMP diode; ancillary equipment; command bay; conical self magnetic pinch diode; high voltage dump tanks; inner stalk; linear transformer driver generator; preventive maintenance operations; radiographic shots; trigger generator; vacuum system; Cavity resonators; Dielectric liquids; Generators; Magnetic liquids; Power transformer insulation; Preventive maintenance; Vacuum systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
Conference_Location :
San Francisco, CA
ISSN :
0730-9244
Type :
conf
DOI :
10.1109/PLASMA.2013.6633491
Filename :
6633491
Link To Document :
بازگشت