    Affine transformation of list mode data for respiratory motion correction in PET

  • Author

    Lamare, F. ; Cresson, T. ; Savean, J. ; Rest, C. Cheze-Le ; Turzo, A. ; Bizais, Y. ; Reader, A.J. ; Visvikis, D.

  • Author_Institution
    Lab. du Traitement de l´´Inf. Medicale, CHU Brest, France
  • Volume
    5
  • fYear
    2004
  • fDate
    16-22 Oct. 2004
  • Firstpage
    3151
  • Abstract
    Respiratory motion is a source of artefacts and reduced image quality in PET. Proposed methodology for correction of respiratory effects involves the use of gated frames, which are however of low signal to noise ratio. Therefore a method accounting for respiratory motion effects without affecting the statistical quality of the reconstructed images is necessary. We have implemented a rigid-body transformation of list mode data for the correction of respiratory motion over the thorax. The study was performed using datasets of the NCAT phantom at different points throughout the respiratory cycle. List mode data based PET simulated frames were produced by combining the NCAT datasets with a Monte Carlo simulation. Transformation parameters accounting for respiratory motion were estimated according to an affine registration and were subsequently applied on the original list mode data. The corrected and uncorrected list mode datasets were subsequently reconstructed using the one-pass list mode EM (OPL-EM) algorithm. Comparison of corrected and uncorrected respiratory motion average frames suggests that an affine transformation in the list mode data prior to reconstruction can produce significant improvements in accounting for respiratory motion artefacts in the lungs and heart. However, the application of a common set of transformation parameters across the imaging field of view does not significantly correct the respiratory effects on organs such as the stomach, liver or spleen.
  • Keywords
    Monte Carlo methods; cardiology; image reconstruction; liver; lung; phantoms; positron emission tomography; Monte Carlo simulation; NCAT phantom; PET; affine transformation; gated frames; heart; list mode data; liver; lungs; one-pass list mode EM algorithm; reconstructed images; respiratory motion correction; rigid-body transformation; spleen; statistical quality; stomach; thorax; Heart; Image quality; Image reconstruction; Imaging phantoms; Lungs; Motion estimation; Positron emission tomography; Signal to noise ratio; Stomach; Thorax;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2004 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8700-7
  • Electronic_ISBN
    1082-3654
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2004.1466349
  • Filename
    1466349