DocumentCode
3548245
Title
Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout
Author
Worstell, W. ; Adler, S. ; Domigan, P. ; Johnson, O. ; Kudrolli, H. ; Lazuka, D. ; Monteverde, P. ; Nevin, J. ; Rohatgi, R. ; Romanov, L. ; Starsja, S.
Author_Institution
PhotoDetection Syst., Inc., Acton, MA, USA
Volume
5
fYear
2004
fDate
16-22 Oct. 2004
Firstpage
3280
Abstract
We have built and characterized the performance of a new whole-body PET/CT scanner. This 90 cm aperture system, with an extended 32 cm axial PET field of view, incorporates a high resolution PET detector utilizing small crystals and wavelength-shifting optical fiber readout. The PET device is operated in 3D mode with no septa, and is integrated with a 90 cm aperture 16-slice CT into a new wide-bore PET/CT system. Results are presented on performance measurements and an overall system description. The system provides the best combined sensitivity, contrast recovery, and spatial resolution of any current PET/CT. System live fraction is very high at clinical activities, due to a combination of highly segmented system optics and a distributed data acquisition system. Singles-based randoms subtraction, real-time live fraction measurement, and spectrally-resolved scatter subtraction are implemented. Phantom measurements demonstrate the new system´s capability to produce high-quality images with low dose to the patient. The system is designed to accommodate the largest patients, potentially reducing claustrophobic reactions and facilitating radiation therapy planning and interventional applications.
Keywords
computerised tomography; data acquisition; image reconstruction; image scanners; medical image processing; particle detectors; positron emission tomography; radiation therapy; 16-slice CT; 3D mode; 90 cm; aperture system; claustrophobic reactions; clinical activities; contrast recovery; crystal detector; distributed data acquisition system; high resolution PET detector; image reconstruction; phantom measurements; prototype whole-body PET/CT scanner; radiation therapy planning; real-time live fraction measurement; singles-based random subtraction; spatial resolution; spectrally-resolved scatter subtraction; wavelength-shifting optical fiber readout; wide-bore PET/CT system; Apertures; Computed tomography; Crystals; Measurement; Optical design; Optical fibers; Optical scattering; Positron emission tomography; Prototypes; Whole-body PET;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8700-7
Electronic_ISBN
1082-3654
Type
conf
DOI
10.1109/NSSMIC.2004.1466389
Filename
1466389
Link To Document