DocumentCode :
3548454
Title :
An improved quadrant-sharing BGO detector for a low cost rodent-research PET (RRPET)
Author :
Wong, W.-H. ; Xie, S. ; Ramirez, R. ; Kim, S. ; Li, H. ; Zhang, Y. ; Uribe, J. ; Wang, Y. ; Baghaei, H.
Author_Institution :
M.D. Anderson Cancer Center, Texas Univ., Houston, TX, USA
Volume :
6
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
3407
Abstract :
This is a study to improve the detector engineering of a low-cost high-sensitivity rodent-research PET camera (RRPET). The detector system is a solid ring of BGO made of tapered-pentagon blocks, each with 8×8 crystals and an average crystal pitch of 2.0 mm. The detector system used a variation of the photomultiplier-quadrant-sharing design (PQS). The first version of the RRPET blocks used white-paint reflectors of different shapes/sizes to control light distribution to the 4 decoding PMT. In this improved version, the white paint was replaced by a new ESR-mirror film. The film is 0.06 mm thick and mechanically robust. The construction provides a very high crystal-packing fraction (96% linearly) with a gap of only 0.08 mm between crystals. The film construction is more suitable for the slab-sandwich-slice construction we developed to make PQS blocks as the film reduces construction time. Average light output increased by 32% compared to the painted version. The light-output ratio (signal uniformity) between the worst crystal group (in the gap between 4 round PMTs) and the best crystal group (near the middle of a PMT) improved from 53% from 63%. The crystal-decoding resolution has also improved. The detection-efficiency uniformity has improved as well. The energy resolution for individual crystals has improved from 24% to 19% for the corner crystals and from 30% to 22% for the central crystals. The film also has better mechanical precision than paint, thereby positioning the small crystals more accurately relative to each other.
Keywords :
photomultipliers; positron emission tomography; solid scintillation detectors; 0.06 mm; 0.08 mm; ESR-mirror film; crystal pitch; crystal-decoding resolution; crystal-packing fraction; energy resolution; light distribution control; mechanical precision; photomultiplier-quadrant-sharing design; quadrant-sharing BGO detector; rodent-research PET; slab-sandwich-slice construction; white-paint reflectors; Cameras; Costs; Crystals; Detectors; Energy resolution; Optical films; Paints; Positron emission tomography; Shape control; Solids;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466618
Filename :
1466618
Link To Document :
بازگشت