    Analysis of the impact of CT based attenuation correction, scatter compensation and 3D-beam modeling on SPECT image quality

  • Author

    Williams, Celeste B. ; Vija, A. Hans ; Rempel, Trudy D. ; Hawman, Eric G. ; Engdahl, John C.

  • Author_Institution
    Nucl. Medicine Group, Siemens Med. Solutions USA Inc., Hoffman Estates, IL, USA
  • Volume
    6
  • fYear
    2004
  • fDate
    16-22 Oct. 2004
  • Firstpage
    3519
  • Abstract
    Non uniform photon attenuation and Compton scatter degrade nuclear medicine SPECT images by removing true counts or adding unwanted counts, respectively. For quantitative SPECT, iterative reconstruction algorithms, such as OSEM, allow 3D collimator modeling and compensation of the effects of scatter and attenuation. In this work, we investigate, through ROI and SPM analysis of phantom and computer simulation studies, how a combination of compensation strategies affects image quality and quantitative accuracy. Phantoms were imaged with a SPECT and a CT scanner. With these acquisitions, semi-quantitative analysis was performed for the following reconstruction strategies: OSEM-3D without attenuation and scatter compensation; OSEM-3D CTAC (with attenuation correction); and OSEM-3D with attenuation and scatter compensation (CTACSC). For the simulated dataset, the SNR was 50.5 with CTACSC compared to 27.5 without any compensation and OSEM-3D CTACSC produced reconstructed images with contrast within 0.23% of the true image with a standard error of 21 counts. Without compensation, the error increases to 2382 counts. The implementation and design of the OSEM-3D CTACSC approach proved effective, with improved visual quality and quantitative accuracy of the SPECT images.
  • Keywords
    Compton effect; collimators; computerised tomography; error compensation; image reconstruction; iterative methods; medical image processing; optimisation; phantoms; single photon emission computed tomography; 3D collimator modeling; 3D-beam modeling; CT based attenuation correction; CT scanner; Compton scatter; ROI; SPECT image quality; SPM; computer simulation; error compensation; iterative reconstruction algorithm; nonuniform photon attenuation; nuclear medicine; ordered subsets expectation maximization; phantom; scatter compensation; semiquantitative analysis; Attenuation; Computed tomography; Degradation; Electromagnetic scattering; Image analysis; Image quality; Image reconstruction; Imaging phantoms; Particle scattering; Single photon emission computed tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2004 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8700-7
  • Electronic_ISBN
    1082-3654
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2004.1466645
  • Filename
    1466645