Spurious low frequency oscillations similar to those reported by Cutler have been observed in the form of large amplitude modulation of both the RF output and the collector current of klystrons utilizing high perveance electron beams. This modulation, which appears typically as saw-tooth-like relaxation oscillations with frequencies ranging from 10 cps to 10 kcps, was observed to occur spontaneously only if the operating pressure was lower than a critical threshold (

mm Hg). Experiments are described which were designed to investigate this phenomenon using dc beam testers. Evidence is presented which indicates that the oscillations are due to a relaxation back and forth between two possible solutions to Poissons equation which both satisfy all boundary conditions. One of the possible solutions corresponds to the existence of a virtual cathode within the beam, resulting in a partial reflection of electrons. Experimental evidence indicates that positive ions play an important role in triggering the relaxation.