• DocumentCode
    3552453
  • Title

    An X-band forward wave DC operated crossed-field amplifier

  • Author

    Feulner, F.A. ; Sussman, S.S.

  • Author_Institution
    S-F-D Laboratories, Inc., Union, N. J.
  • Volume
    12
  • fYear
    1966
  • fDate
    1966
  • Firstpage
    18
  • Lastpage
    18
  • Abstract
    An X-band, dc operated, forward wave, crossed-field amplifier has been developed utilizing a helix coupled vane structure as the slow wave circuit. The amplifier, designed for phased array applications, is contained in a 6-inch diameter magnetically shielded package 10.5 inches long, weighing 26.5 pounds. This tube uses an emitting sole and a debunched reentrant electron stream. Debunching is accomplished in a drift space located between input and output waveguide matching sections. THe tube is operated from a dc power supply. Cathode current flow is initiated by the RF input signal and is turned off at the end of the RF drive pulse by the application of a short voltage pulse to a turn off electrode.
  • Keywords
    Blades; Coupling circuits; Electron emission; Electron tubes; Impedance matching; Magnetic shielding; Packaging; Phased arrays; Pulsed power supplies; Radio frequency;
  • fLanguage
    English