DocumentCode
3552453
Title
An X-band forward wave DC operated crossed-field amplifier
Author
Feulner, F.A. ; Sussman, S.S.
Author_Institution
S-F-D Laboratories, Inc., Union, N. J.
Volume
12
fYear
1966
fDate
1966
Firstpage
18
Lastpage
18
Abstract
An X-band, dc operated, forward wave, crossed-field amplifier has been developed utilizing a helix coupled vane structure as the slow wave circuit. The amplifier, designed for phased array applications, is contained in a 6-inch diameter magnetically shielded package 10.5 inches long, weighing 26.5 pounds. This tube uses an emitting sole and a debunched reentrant electron stream. Debunching is accomplished in a drift space located between input and output waveguide matching sections. THe tube is operated from a dc power supply. Cathode current flow is initiated by the RF input signal and is turned off at the end of the RF drive pulse by the application of a short voltage pulse to a turn off electrode.
Keywords
Blades; Coupling circuits; Electron emission; Electron tubes; Impedance matching; Magnetic shielding; Packaging; Phased arrays; Pulsed power supplies; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices Meeting, 1966 International
Type
conf
DOI
10.1109/IEDM.1966.187644